TG0019A
(CONT’D)
Section 6: Troubleshooting the EPM
Batteries are connected
TT
TT
T
Vehicle battery-connect button
is pressed.
3-Minute counter in EPM starts.
TT
TT
T
Chart 7 – 28V Only – EPM Sequence of Operation
Flashing GREEN
TT
TT
T
START-RUN Switch operated to start vehicle
TT
TT
T
Batteries will stay connected as long as vehicle is running
or emergency flashers are on
TT
TT
T
TT
TT
T
Normal operation
TT
TT
T
Shut down vehicle
Flashing GREEN
3-Minute Delay
3-Minute Delay Ends and EPM disconnects batteries
AUX LEDs Steady GREEN
AUX Current available
TT
TT
T
TT
TT
T
TT
TT
T
TT
TT
T
If emergency flashers are the
only load required, engine
does not need to be started to
keep batteries connected. After
flashers are switched on, EPM
will keep power to loads until
batteries are discharged.
TT
TT
T
EPM and AUX Diagnostic LEDs OFF.
AUX Channels still available.
TT
TT
T
TT
TT
T
3-Minute delay in EPM ends
TT
TT
T
TT
TT
T
If you have questions about your alternator or any of these test procedures, or if you need to locate a Factory Authorized Service Distributor, please contact us at: